Why Is My Furnace Leaking Water? What to Do Next

Carrier furnace leaking water.
A furnace leaking water is a sight no homeowner wants to see. If you’ve found a puddle around your furnace, you’re probably wondering what’s wrong and how much it will cost to fix.
 
If you’ve found water pooling around your furnace, don’t panic. It’s one of the most common issues we see here in Southeast Michigan, and the cause is usually more straightforward than you might think.
 
Most furnace leaks have simple explanations, and some can even be identified before you need to call a professional. This guide will walk you through the process of figuring out why your furnace is leaking and what your next steps should be.
 

Does a Gas Furnace Even Create Water?

First, it’s helpful to understand how your furnace operates. When your thermostat signals for heat, a gas furnace ignites natural gas within a component called a heat exchanger. As the heat exchanger gets hot, a blower fan pushes your home’s cool air past it. This heated air then circulates through your vents to warm the house.
 
The question of where water comes from depends entirely on the type of furnace you own.
 
A standard-efficiency furnace does not produce water as part of its normal operation. In contrast, a high-efficiency furnace, also known as a condensing furnace, creates water by design. These systems feature a second heat exchanger that extracts additional heat from the exhaust gases before they exit your home. As these gases cool, water vapor condenses into a liquid that must be drained away.
 
This is why high-efficiency models are equipped with drain lines, condensate pumps, and traps. When this system functions correctly, the water is disposed of without you ever noticing. A problem in the drainage system is what leads to a puddle on your floor.
 

What Kind of Furnace Do I Have?

Identifying your furnace type is the essential first step, as it determines the likely source of the leak. You can figure this out by looking at the exhaust pipe that vents gases outside.

high-efficiency condensing furnace

High Efficiency

White PVC Pipe: You have a high-efficiency condensing furnace.

standard condensing furnace

Standard Efficiency

Metal Pipe: You have a standard-efficiency furnace.

 If you have a standard-efficiency model with a metal exhaust, the water is not coming from the furnace itself. The source is almost certainly a nearby appliance, such as your air conditioner, a whole-home humidifier, or a water heater.
 
If you have a high-efficiency model with a PVC exhaust, the leak is directly related to your furnace’s condensate system.
 

Common Causes of Leaks in High-Efficiency Furnaces

High-efficiency furnaces produce a significant amount of condensation. When the drainage system is compromised, water has nowhere to go but out onto the floor. Here are the most frequent culprits.
 

Clogged Condensate Line

This is the leading cause of furnace leaks. The condensate drain line, a small hose or pipe, carries water from the furnace to a floor drain or pump. Over time, this line can become blocked with dust, algae, and other debris. When the line is clogged, water backs up and overflows.
 

Blocked Condensate Trap

Many furnaces have a condensate trap, similar in function to the P-trap under a sink. It holds a small amount of water to prevent exhaust gases from entering your home. If this trap becomes clogged with sediment, it will cause water to back up and spill.
 

Failed Condensate Pump

If your furnace is located far from a floor drain, it likely uses a condensate pump to move the water. These pumps have a typical lifespan of three to five years. When a pump fails or its internal float switch gets stuck, the collection basin overflows.
 

Cracked Inducer Assembly

Condensation forms inside the inducer assembly, which is a component that pulls exhaust gases through the furnace. If a crack develops in the assembly or its seals fail, water can leak out before it reaches the drainage system.
 

When a Standard-Efficiency Furnace Seems to Leak

If you have a standard-efficiency furnace (with a metal exhaust pipe), the water you’re seeing is coming from another source. Your furnace is just an unfortunate neighbor. Here are the usual suspects.
 

Your Air Conditioner is the Real Culprit

This is the most common scenario. Your AC’s indoor unit sits on or next to your furnace and produces its own condensation. If you see water in the summer or early fall, your AC is the prime suspect.
 
  • Clogged AC Drain: Just like a furnace, an AC drain line can get clogged with algae and debris, causing a backup.
  • Cracked Drain Pan: The indoor coil sits in a drain pan. Over time, these pans can rust or crack, allowing water to drip onto the floor.
  • Frozen Evaporator Coil: A dirty air filter or low refrigerant can cause the AC’s evaporator coil to freeze. When it thaws, the sudden rush of water can overwhelm the drain pan and cause a spill.

 

A Leaking Whole-Home Humidifier

Many homes in our area have a humidifier attached to the furnace ductwork. These units have their own water supply lines that can crack, loosen, or break, leading to a leak that appears to come from the furnace, especially during the heating season.
 

A Nearby Water Heater Leak

Check any adjacent water heaters. A leak from a drain valve or a crack in the tank can easily pool around the base of the furnace, making it seem like the source of the problem.

Is a Furnace Leak Dangerous?

While a furnace leak is not an immediate, life-threatening emergency, it should never be ignored. The longer you wait, the more significant the potential damage becomes.
 
  • Mold and Mildew: Standing water creates a breeding ground for mold, which can degrade your home’s air quality and trigger allergy or asthma symptoms.
  • Electrical Damage: Water can corrode or short out critical electrical components inside your furnace, including the main circuit board. This turns a simple fix into a costly repair.
  • Heat Exchanger Rust: In a worst-case scenario, persistent water exposure can cause the heat exchanger to rust and crack. A cracked heat exchanger is a serious safety hazard, as it can allow carbon monoxide to leak into your home. This is rare, but it highlights the importance of addressing any leak promptly.

 

What to Do When You Find a Furnace Leak

Taking a few immediate steps can prevent further damage while you diagnose the issue.
 
  1. Turn Off the Power: For your safety and to prevent electrical damage, shut off the power to your furnace. You can do this at the thermostat, via the power switch next to the furnace, or at your home’s circuit breaker.
  2. Clean Up the Water: Use towels or a wet-dry vacuum to remove all standing water. The quicker you dry the area, the lower the risk of mold growth and rust.
  3. Perform a Visual Inspection: If you have a high-efficiency furnace, trace the condensate drain line from the furnace to the drain. Look for obvious kinks, disconnections, or visible blockages.
  4. Call a Licensed HVAC Professional: Even if you find and clear a simple clog, it is wise to have a professional inspect the system. A trained technician can spot underlying issues, check for hidden water damage, and ensure your furnace is operating safely.

 

How Much Does It Cost to Fix a Furnace Leak in Oakland County?

The cost of repair depends entirely on the cause. For a simple fix like clearing a clogged condensate line, you can expect to pay between $150 and $300. If the condensate pump needs to be replaced, the cost is typically between $250 and $500. More complex furnace repairs, such as replacing a cracked inducer assembly, can cost $400 to $800 or more.
Fortunately, the vast majority of furnace leaks are simple and fall into the lower end of that price range.
 

How to Prevent Future Furnace Leaks

The best way to handle furnace leaks is to prevent them from happening in the first place. Regular maintenance is key.
 
  • Annual Furnace Tune-Ups: A yearly tune-up is the single most effective preventive measure. During this service, a technician will clean the condensate drain system, inspect the pump, and check all critical components for wear and tear.
  • Change Your Air Filter: A clogged filter restricts airflow, which can cause a host of problems, including a frozen AC coil that leads to water overflow. Check your filter every month and replace it at least every three months.
  • Maintain Your Drain Line: Between professional visits, you can help keep your condensate line clear by slowly pouring a cup of distilled white vinegar down the line every couple of months. This helps prevent algae and sludge buildup.
 
For homeowners who want total peace of mind, a maintenance plan is an excellent investment. These plans include scheduled tune-ups, priority service, and discounts on repairs, often for less than the cost of a single emergency service call.
 

Your Local Furnace Experts in Oakland County

When you’re facing a furnace leak, you need a reliable expert who can diagnose the problem correctly and fix it fast. Oakland Heating & Cooling has served homeowners across Southeast Michigan for over 20 years. Our licensed and insured technicians are trained to find the true source of a leak, not just treat the symptom.
 
We offer same-day service throughout Oxford, Lake Orion, Royal Oak, Troy, and the surrounding areas because we know that heating and cooling issues can’t wait. If you see water around your furnace, don’t wait for the problem to get worse. Contact Oakland Heating & Cooling today for fast, professional service.
 

Frequently Asked Questions

Why is my furnace leaking water from the bottom?

Water leaking from the bottom of your furnace typically means the condensate drainage system isn’t working properly. If you have a high-efficiency furnace, the most common causes are a clogged drain line, a failed condensate pump, or a blocked condensate trap. If you have a standard-efficiency furnace with a metal exhaust pipe, the water is likely coming from your air conditioner, humidifier, or another nearby appliance rather than the furnace itself.

Is it normal for a furnace to leak a little water?

No, it is not normal for any amount of water to pool around your furnace. While high-efficiency furnaces do produce condensation as part of their operation, this water should drain away completely through the condensate system. Even a small leak indicates a problem that will get worse over time if not addressed. What starts as a damp spot can quickly turn into standing water and cause mold growth or damage to your furnace components.

Can I run my furnace if it's leaking water?

You should turn off your furnace if you discover a water leak. Running the furnace while it’s leaking can cause additional water damage, promote mold growth, and potentially damage electrical components inside the unit. Water and electricity are a dangerous combination, and continuing to operate a leaking furnace could lead to short circuits or more expensive repairs. Shut off the power and call a licensed HVAC technician to diagnose and fix the problem.

Why does my furnace only leak water when the heat is on?

If water only appears when you’re running the heat, you likely have a high-efficiency condensing furnace with a drainage problem. These furnaces produce condensation during the heating process, and when your system runs constantly during cold weather, it generates more water than usual. A clogged condensate line or a failing pump can’t keep up with the volume of water, causing it to overflow. This is especially common during the coldest weeks of winter when your furnace runs nonstop.

Why is my furnace leaking water in the summer?

If you see water around your furnace during the summer months, your air conditioner is almost certainly the culprit, not your furnace. The AC’s indoor evaporator coil sits near or on top of your furnace and produces a significant amount of condensation during cooling season. Common causes include a clogged AC drain line, a cracked drain pan, or a frozen evaporator coil that has thawed and dumped excess water. Check your AC system first before assuming the furnace is the problem.

Can a leaking furnace cause carbon monoxide?

A furnace leak itself does not directly cause carbon monoxide poisoning. However, if water damage causes your heat exchanger to rust and crack over time, the cracked heat exchanger can allow carbon monoxide to leak into your home. This is a rare but serious safety concern. Water can also corrode other furnace components and create unsafe operating conditions. This is why it’s important to address any furnace leak promptly and have a professional inspect your system for hidden damage.

How do I stop my furnace from leaking water?

For immediate action, turn off the power to your furnace and clean up any standing water. If you have a high-efficiency furnace, check the condensate drain line for obvious clogs or disconnections. You may be able to clear a simple blockage yourself, but it’s best to call a licensed HVAC technician to properly diagnose and repair the issue. To prevent future leaks, schedule annual furnace maintenance, change your air filter regularly, and pour a cup of white vinegar down the condensate line every few months to prevent algae buildup.

Do I need to replace my furnace if it's leaking water?

In most cases, no. A leaking furnace rarely requires full replacement. The vast majority of furnace leaks are caused by simple drainage issues that can be repaired quickly and affordably. You would only need to consider furnace replacement if the leak has caused extensive damage to critical components like the heat exchanger, or if your furnace is already old and near the end of its expected lifespan. A qualified HVAC technician can assess the damage and recommend whether repair or replacement makes more sense for your situation.